Cognex Knowledge Base Search
|
|
| Latest 1.3 Version: 1.3 SmartReader Beta 13 |
| Release Date: Sep 23 2002 12:00AM |
Known Issues |
|
|
|
|
|
|
|
|
|
|
|
Other |
| Output Timing/Inspection Termination Issue |
| Version Effected: 1.1 Beta 7 SmartReader |
Version Fixed: |
Status: Open |
| If Outputs are configured for "Immediately, but within X ms after trigger", there is an issue with the termination of the inspection. The internal clock is reviewed after each SoftSensor has finished executing to determine the inspection time. If there is a SoftSensor that takes a long time to execute (non-optimized OCR failure), and it starts inspecting just prior to the Output time-out, the timer is not polled again until after SoftSensor has finished inspecting. This is an issue if there is a new trigger coming just after the timer times out - you will end up with a resource conflict. |
| 1D Grading not available in SmartReader |
| Version Effected: 1.2 SmartReader Beta 15 |
Version Fixed: |
Status: Open |
| The 'SoftSensors Settings' tab in the Options dialog is not available on SmartReaders. This means the 'Enable 1D Grading Beta' selection can not be set to make the grading tabs appear in the 1D barcode dialog. |