Cognex Knowledge Base Search

KnowledgeBase Home

Latest 1.3 Version: 1.3 FrameWork
Release Date: Mar 23 1999 12:00AM

Known Issues

Other

Average Intensity values shift every time Apply is entered.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
Within the Blob Selector tool's Parameters tab check the Avg. Intensity box and enter a value for either the min. or max. (other than the defaults). Press Apply. The values will shift by a fractional amount. Repeated applications of Apply will each cause
When saving products to PC the Data Link strings are sometimes left out
Version Effected: 1.3 FrameWork Version Fixed: 2.1.1 Release FrameWork Status: Verified Fixed
When the product is saved to the PC the data link strings for some or all products are not saved. This has been traced to the UI not having successfully read the data when querying product parameters.
Changing to the datalink driver will switch to the driver and then not accept any commands or send any output.
Version Effected: 1.3 FrameWork Version Fixed: 2.1.1 Release FrameWork Status: Verified Fixed
After changing to datalink, you could not change back to the system terminal driver to initiate FrameWork or System Terminal commands. This has been fixed. The *T- system command changes the datalink terminal back to the system terminal mode. You can then use the #Tb and #Tt command to permanently set the port to system terminal. This is all handled automatically by FrameWork now.
Terminal times out while connecting to a system with many products.
Version Effected: 1.3 FrameWork Version Fixed: 2.1.1 Release FrameWork Status: Verified Fixed
After loading the attached *.dvt file to an 800 the FrameWork UI will not be able to reconnect. Everything works fine loading the product file but the problem appears after the UI has disconnected from the system and tries to reconnect.
FrameWork UI looses communication when long output pulse widths are used.
Version Effected: 1.3 FrameWork Version Fixed: Status: Reproduced
A dialog box is displayed that states "Communications has been lost with the SmartImage sensor, would you like to disable communications". The status/ready LED light is constantly off. This is typically caused by having an output pulse width larger than your time between triggers.
Terminal window for datalink is not wide enough for long outputs.
Version Effected: 1.3 FrameWork Version Fixed: 2.2 Release FrameWork Status: Verified Fixed
If a Blob Selector SoftSensor is being used as a Locator, the position check box in the softsensors parameter page must be enabled
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified As Designed
When referencing a Blob Selector SoftSensor for position, the softsensor fails and the results table failure mode is indicated as "Position Failed" If the position check box in the Blob Selector SoftSensor is not enabled, then there is no correct posit
The y axis label for the Roundness graph for precision measurement softsensors indicates roundness is pixels even if it is scaled.
Version Effected: 1.3 FrameWork Version Fixed: 2.2 Release FrameWork Status: Verified Fixed
Axis on roundness graph mistakenly states roundness is in pixel when the value is scaled. When scaling a precision circle fit softsensor, the roundness measurement as well as the radius are scaled. However, the roundness graph's y axis label is mistak
Outputs seem to be not available when using a multiplexer and the toggle output.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified As Designed
The toggle digital output toggles after each head instead of when the outputs are available.
Strange datalink values show up in the terminal window.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
If the sensor is failing when a parameter entry is created for it the type is changed to 'character' regardless of the default type.
Memory allocation error in the results table for measurement softsensor. Funky random shut down of system after a period of time. May cause system to crash and LED lights on 800 to alternately flash.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
The Measure Across Area and Area Edge SoftSensors in the Precision Measurement toolbox will cause a memory allocation error if any of the advanced measurement settings are seleced besides line fit. Memory allocation will show up in the results table as a
A dialog box is displayed that states "Communications has been lost with the SmartImage sensor, would you like to disable communications". The busy LED light is constantly on and ready LED light is constantly off.
Version Effected: 1.3 FrameWork Version Fixed: Status: Open
Communications with the SmartImage sensor appears to stop due to an overtaxing of the SmartImage sensors processor. The usually occurs when inspections are running internal trigger at full speed and there is a long output pulse width is defined.
Memory allocation is indicated in the results table for a small circular softsensor. A small circle or arc is drawn incorrectly in the sampled image display.
Version Effected: 1.3 FrameWork Version Fixed: Status: Open
When drawing a small circle or arc less than 7 pixels in diameter, there are not enough points to approximate the circle. This causes a memory allocation error in the firmware which causes the system to eventually run out of memory causing the system to fail.
Datalink strings seem to disappear or be wrong when product files are restored from the PC.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
The datalink string are sometimes missing due to the fact that the information is not queried from the smartimage sensor. To make the data current on the userinterface, each product can be reselected. This ensures all the data is correct.
Communications locks up when starting up the user interface when a large number of product files is present on the system.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
Communications locks up when starting up the user interface when a large number of product files is present on the system.
"Error executing Script" is generated in the script softsensors when referencing NumbBlobs.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Fixed
The new Script Math SoftSensor cannot reference the parameter NumBlobs of a SoftSensor in a script file. An error executing script will be generated by the compiler in the script tab dialog.
No information is seen in a pixel graph or gradient graph for the new segmented find circle arc softsensor.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
The segmented arc softsensor graphs sometimes shows strange information. This is due to the fact that the softsensor graphs the information for the edge scan located at the 3 o'clock position. If there is no edge there, then the graph contains no data.
Product and/or softsensors start failing without cause. The threshold of a softsensor seems to have changed without cause.
Version Effected: 1.3 FrameWork Version Fixed: 2.2 Release FrameWork Status: Verified Fixed
FrameWork 1.3 allows the threshold of a softsensor to be changed directly on a graph on the desktop by clicking on the appropriate threshold value. This was done to make it easier to set a threshold value. However, since a single mouse click changes the
Numbers formatted as ASCII characters are not output for Datalink.
Version Effected: 1.3 FrameWork Version Fixed: 1.3 FrameWork Status: Verified Fixed
In datalink it is documented that values can be formatted as a character. This should give an equivalent ASCII character when it is applicable. However, this formatting was not implemented in FrameWork 1.3.
Invalid Param shows up in the sample display for datalink and Invalid Format shows up in the terminal window.
Version Effected: 1.3 FrameWork Version Fixed: 2.1 Release FrameWork Status: Verified Fixed
The gradient threshold for datalink has not been implemented in FrameWork 1.3.
Invalid Parameter shows up in the terminal window for datalink.
Version Effected: 1.3 FrameWork Version Fixed: 2.1.1 Release FrameWork Status: Verified Fixed
The scale factor should not be shown as a valid parameter under individual measurement softsensors.
Boundary blobs are counted when count boundary blobs is disabled.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
Boundary blobs are counted even when count boundary blobs are disabled
String data cannot be viewed in the terminal window of DataLink
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified Fixed
The terminal window is not size properly to match the string length before wrapping to the next line.
"Cannot reference own outputs" shows up when compling script tools.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified as Designed
When writing a script, the outputs of the script softsensor cannot be referenced. They can only be set.
When referencing subpixel position of a Blob Selector SoftSensor, the wrong position can sometimes be used without warning.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified as Designed
The wrong position of a blob selector softsensor is sometime sent to the coordinate transformation softsensor when more than one blob is sent from a generator blob tool to a selector blob tool. This occurs because the first blob is always the upper most blob.
A script tool gets a "syntax error" on the line which has a <> (not equal) operator on it.
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
The not equal operator does not work in the Script SoftSensor and it causes a syntax error.
The intensity parameter setting shifts by a fractional amount when the apply or ok buttons are pressed.
Version Effected: 1.3 FrameWork Version Fixed: 2.1.1 Release FrameWork Status: Verified Fixed
The intensity parameters are rounded incorrectly when they are sent to the processor. Therefore, each time the apply button or the ok button is pressed in the blob softsensor, the parameters change by a fractional amount.
The roundness value for the find circle or segmented arc softsensor is missing from datalink
Version Effected: 1.3 FrameWork Version Fixed: 1.3B24 FrameWork Status: Verified Fixed
The roundness value does not show up in the drop-down in the string tab for the datalink.
"Error executing Script" is generated in the compiler results of the script.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified as Designed
The script tool itself is not recognized in the script until you hit apply, since new SoftSensors are only created when you hit apply or OK. However, once you hit apply or OK, the SoftSensor will start being used for inspection purposes.
Axis on roundness graph mistakenly states roundness is in pixel when the value is scaled.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified Fixed
When scaling a precision circle fit softsensor, the roundness measurement as well as the radius are scaled. However, the roundness graph's y axis label is mistaken labeled still as in pixels when the value is actually scaled correctly.
Coordinate Transformation softsensor generated incorrect values when referencing a Blob Selector SoftSensor.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified as Designed
The position and angle check boxes in the Blob Selector SoftSensor parameters page must be enabled, otherwise no position is calculated and there is no correct position to reference.
The feature size parameter appear to change on the user.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified as Designed
The minimum feature size must be less than the maximum feature size, if this is reversed the two values are automatically switched without notifying the user.
F8 does not bring up the histogram graph for a blob generator softsensor.
Version Effected: 1.3 FrameWork Version Fixed: 2.1.1 Release FrameWork Status: Verified Fixed
When you have the blob generator selected F8 brings up the Pass/Warn/Fail graph instead of the histogram graph.
The Table of Contents file does not show up for the Help file in FrameWork 1.3
Version Effected: 1.3 FrameWork Version Fixed: 1.4 Beta 5 FrameWork Status: Verified Fixed
The necessary fwk.cnt file is not installed when you run the FrameWork 1.3 installation program.
The SmartImage sensor fails inspections, however the SID and results table passes.
Version Effected: 1.3 FrameWork Version Fixed: Status: Verified As Designed
This is related to a timing issue caused by incorrect system setup. If you go to the Ssytem Inspection Statistics graph you will see missed inspections and/or resource conflicts. Check areas related to timing: Delay after trigger, inspection period, output pulse width.
Advanced Measurement softsensor parameters can cause SmartImage sensor to intermittently crash.
Version Effected: 1.3 FrameWork Version Fixed: 1.4 FrameWork Status: Verified Fixed
Some advanced measurement softsensor setting can cause the smartimage sensor to crash due to a divide by zero. This will occur if no edges are found on a measure across area softsensor on a black image with mean distance selected on the advanced paramete

Confusion Points

Intensity values sent by Datalink and used by Script SoftSensors do not appear to be correct.
Version Effected: 1.3 FrameWork Version Fixed:
Intensity values used in the Script SoftSensor and in Data Link are Integer values between 0 and 10000. These values are actually the percent darkness scaled by 100 in order to achieve an integer value.